Top image

Macromolecular CrystallographyBeamline BW7B

Beamline BW7B is a wiggler macromolecular crystallography beamline on the DORIS BW7 wiggler, located in the HASYLAB Hall 5. It is a monochromatic fixed wavelength beamline operated at a wavelength of 0.84 Å (14.8 keV). The endstation is equipped with a Mar 345-mm IP detector. The beamline is dedicated to the development of the automatic sample changer system MARVIN of EMBL Hamburg.

Contact:

Scientist in charge of MARVIN

Stefan Fiedler,  Tel: +49 40 89902-195,  Email: stefan.fiedler@embl-hamburg.de

MX Coordinator

Victor Lamzin, Tel: +49 40 89902-121, Email: victor@embl-hamburg.de

Beamline BW7B

Tel: +49 40 89902-172

 Experimental possibilities with MARVIN

  • Pre-screening of crystals before data collection
  • Up to 150 samples corresponding to 15 baskets can be loaded
  • SPINE standard pins and revolver SC3 baskets must be used (the baskets may be borrowed from the outstation)
  • Barcode reading
  • Automatic centering

Facts

Synchrotron source 1 Tesla multi-pole wiggler (28 poles, 14 cm period)
Mirror 1 Flat pre-mirror
Monochromator Si (111), horizontally focussing
Mirror 2 Bent, vertically focussing
Additional elements: Not applicable
Wavelength 0.84 Å
Focal spot 2 mm x 0.4 mm (FWHM)
Flux Not applicable
Slits 0.1 x 0.1 to 2 x 2 mm
Cryo-system Oxford 600 series
Sample changer MARVIN
Crystal centring Automatic (MARVIN)
Goniometer Single axis
Spindle rotation Minimum 1 s/degree
Detector MARIP 345 mm
Crystal-detector distance 96–1250 mm